summaryrefslogtreecommitdiffhomepage
path: root/applications/luci-app-nut
diff options
context:
space:
mode:
authorPascal Coudurier <coudu@wanadoo.fr>2022-01-05 18:03:49 +0100
committerPascal Coudurier <coudu@wanadoo.fr>2022-01-05 18:03:49 +0100
commitb75d7b0e5da1c33624ed56b840e260ebcddda63e (patch)
tree3aa293bc89f2c504131dafbaf475488d65fe3e1a /applications/luci-app-nut
parentdc0ed9ca93c842d48613003e6f47b66c373e7148 (diff)
luci-app-nut: nut-monitor fixes
Fix typo in lowbattnotify option Remove duplicate lowbattnotify option Fix notify validation preventing IGNORE to be set even alone Add missing nocommnotify and noparentnotify options Signed-off-by: Pascal Coudurier <coudu@wanadoo.fr>
Diffstat (limited to 'applications/luci-app-nut')
-rw-r--r--applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua28
-rw-r--r--applications/luci-app-nut/po/templates/nut.pot62
2 files changed, 54 insertions, 36 deletions
diff --git a/applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua b/applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua
index 2496259bad..b1bb1b850f 100644
--- a/applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua
+++ b/applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua
@@ -78,9 +78,9 @@ o.optional = true
validatenotify = function(self, value)
val = StaticList.validate(self, value)
if val then
- for k, v in pairs(val) do
- if (v == 'IGNORE') then
- return nil, "Ignore must the only option selected, when selected"
+ for i, v in ipairs(val) do
+ if (i > 1) and (v == 'IGNORE') then
+ return nil, "If selected, Ignore must be the only option."
end
end
end
@@ -112,7 +112,7 @@ o:value("SYSLOG", translate("Write to syslog"))
o:value("IGNORE", translate("Ignore"))
o.validate = validatenotify
-o = s:option(StaticList, "nowbattnotify", translate("Notify when low battery"))
+o = s:option(StaticList, "lowbattnotify", translate("Notify when low battery"))
o.optional = true
o.widget = "select"
o:value("EXEC", translate("Execute notify command"))
@@ -120,7 +120,7 @@ o:value("SYSLOG", translate("Write to syslog"))
o:value("IGNORE", translate("Ignore"))
o.validate = validatenotify
-o = s:option(StaticList, "nowbattnotify", translate("Notify when low battery"))
+o = s:option(StaticList, "fsdnotify", translate("Notify when force shutdown"))
o.optional = true
o.widget = "select"
o:value("EXEC", translate("Execute notify command"))
@@ -128,7 +128,7 @@ o:value("SYSLOG", translate("Write to syslog"))
o:value("IGNORE", translate("Ignore"))
o.validate = validatenotify
-o = s:option(StaticList, "fsdnotify", translate("Notify when force shutdown"))
+o = s:option(StaticList, "comoknotify", translate("Notify when communications restored"))
o.optional = true
o.widget = "select"
o:value("EXEC", translate("Execute notify command"))
@@ -136,7 +136,7 @@ o:value("SYSLOG", translate("Write to syslog"))
o:value("IGNORE", translate("Ignore"))
o.validate = validatenotify
-o = s:option(StaticList, "comoknotify", translate("Notify when communications restored"))
+o = s:option(StaticList, "combadnotify", translate("Notify when communications lost"))
o.optional = true
o.widget = "select"
o:value("EXEC", translate("Execute notify command"))
@@ -144,7 +144,7 @@ o:value("SYSLOG", translate("Write to syslog"))
o:value("IGNORE", translate("Ignore"))
o.validate = validatenotify
-o = s:option(StaticList, "combadnotify", translate("Notify when communications lost"))
+o = s:option(StaticList, "shutdownotify", translate("Notify when shutting down"))
o.optional = true
o.widget = "select"
o:value("EXEC", translate("Execute notify command"))
@@ -152,7 +152,7 @@ o:value("SYSLOG", translate("Write to syslog"))
o:value("IGNORE", translate("Ignore"))
o.validate = validatenotify
-o = s:option(StaticList, "shutdownotify", translate("Notify when shutting down"))
+o = s:option(StaticList, "replbattnotify", translate("Notify when battery needs replacing"))
o.optional = true
o.widget = "select"
o:value("EXEC", translate("Execute notify command"))
@@ -160,7 +160,15 @@ o:value("SYSLOG", translate("Write to syslog"))
o:value("IGNORE", translate("Ignore"))
o.validate = validatenotify
-o = s:option(StaticList, "replbattnotify", translate("Notify when battery needs replacing"))
+o = s:option(StaticList, "nocommnotify", translate("Notify when no communications"))
+o.optional = true
+o.widget = "select"
+o:value("EXEC", translate("Execute notify command"))
+o:value("SYSLOG", translate("Write to syslog"))
+o:value("IGNORE", translate("Ignore"))
+o.validate = validatenotify
+
+o = s:option(StaticList, "noparentnotify", translate("Notify when no parent process"))
o.optional = true
o.widget = "select"
o:value("EXEC", translate("Execute notify command"))
diff --git a/applications/luci-app-nut/po/templates/nut.pot b/applications/luci-app-nut/po/templates/nut.pot
index 4b5416a6f2..b8e7675afd 100644
--- a/applications/luci-app-nut/po/templates/nut.pot
+++ b/applications/luci-app-nut/po/templates/nut.pot
@@ -14,8 +14,8 @@ msgid "Allowed actions"
msgstr ""
#: applications/luci-app-nut/luasrc/model/cbi/nut_cgi.lua:20
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:188
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:217
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:196
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:225
msgid "As configured by NUT"
msgstr ""
@@ -23,7 +23,7 @@ msgstr ""
msgid "Bytes to read from interrupt pipe"
msgstr ""
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:174
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:182
msgid "CA Certificate path"
msgstr ""
@@ -120,6 +120,7 @@ msgstr ""
#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:150
#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:158
#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:166
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:174
msgid "Execute notify command"
msgstr ""
@@ -151,8 +152,8 @@ msgstr ""
msgid "Hostname or IP address"
msgstr ""
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:191
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:220
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:199
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:228
msgid "Hostname or address of UPS"
msgstr ""
@@ -174,6 +175,7 @@ msgstr ""
#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:152
#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:160
#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:168
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:176
msgid "Ignore"
msgstr ""
@@ -250,8 +252,8 @@ msgstr ""
msgid "NUT Users"
msgstr ""
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:188
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:217
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:196
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:225
msgid "Name of UPS"
msgstr ""
@@ -314,32 +316,39 @@ msgstr ""
msgid "Notify when back online"
msgstr ""
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:163
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:155
msgid "Notify when battery needs replacing"
msgstr ""
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:147
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:139
msgid "Notify when communications lost"
msgstr ""
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:139
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:131
msgid "Notify when communications restored"
msgstr ""
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:131
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:123
msgid "Notify when force shutdown"
msgstr ""
#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:115
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:123
msgid "Notify when low battery"
msgstr ""
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:163
+msgid "Notify when no communications"
+msgstr ""
+
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:171
+msgid "Notify when no parent process"
+msgstr ""
+
#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:107
msgid "Notify when on battery"
msgstr ""
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:155
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:147
msgid "Notify when shutting down"
msgstr ""
@@ -359,13 +368,13 @@ msgstr ""
msgid "Online message"
msgstr ""
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:208
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:237
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:216
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:245
#: applications/luci-app-nut/luasrc/model/cbi/nut_server.lua:19
msgid "Password"
msgstr ""
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:174
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:182
msgid "Path containing ca certificates to match against host certificate"
msgstr ""
@@ -398,15 +407,15 @@ msgid "Polling Frequency(s)"
msgstr ""
#: applications/luci-app-nut/luasrc/model/cbi/nut_cgi.lua:27
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:195
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:224
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:203
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:232
#: applications/luci-app-nut/luasrc/model/cbi/nut_server.lua:46
#: applications/luci-app-nut/luasrc/model/cbi/nut_server.lua:202
msgid "Port"
msgstr ""
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:200
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:229
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:208
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:237
msgid "Power value"
msgstr ""
@@ -418,7 +427,7 @@ msgstr ""
msgid "Replace battery message"
msgstr ""
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:178
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:186
msgid "Require SSL and make sure server CN matches hostname"
msgstr ""
@@ -509,7 +518,7 @@ msgstr ""
msgid "Time in seconds that upsdrvctl will wait for driver to finish starting"
msgstr ""
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:183
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:191
msgid "UPS Master"
msgstr ""
@@ -517,7 +526,7 @@ msgstr ""
msgid "UPS Server Global Settings"
msgstr ""
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:212
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:220
msgid "UPS Slave"
msgstr ""
@@ -549,8 +558,8 @@ msgid ""
"be read-write for that user."
msgstr ""
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:205
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:234
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:213
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:242
#: applications/luci-app-nut/luasrc/model/cbi/nut_server.lua:16
msgid "Username"
msgstr ""
@@ -559,7 +568,7 @@ msgstr ""
msgid "Vendor (regex)"
msgstr ""
-#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:178
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:186
msgid "Verify all connection with SSL"
msgstr ""
@@ -577,6 +586,7 @@ msgstr ""
#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:151
#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:159
#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:167
+#: applications/luci-app-nut/luasrc/model/cbi/nut_monitor.lua:175
msgid "Write to syslog"