diff options
Diffstat (limited to 'applications/luci-app-advanced-reboot/luasrc')
-rw-r--r-- | applications/luci-app-advanced-reboot/luasrc/controller/advanced_reboot.lua | 116 | ||||
-rw-r--r-- | applications/luci-app-advanced-reboot/luasrc/view/advanced_reboot/advanced_reboot.htm | 8 |
2 files changed, 104 insertions, 20 deletions
diff --git a/applications/luci-app-advanced-reboot/luasrc/controller/advanced_reboot.lua b/applications/luci-app-advanced-reboot/luasrc/controller/advanced_reboot.lua index 2b55217b8..13d1c73cc 100644 --- a/applications/luci-app-advanced-reboot/luasrc/controller/advanced_reboot.lua +++ b/applications/luci-app-advanced-reboot/luasrc/controller/advanced_reboot.lua @@ -5,15 +5,18 @@ module("luci.controller.advanced_reboot", package.seeall) -- device, board_name, part1, part2, offset, env_var_1, value_1_1, value_1_2, env_var_2, value_2_1, value_2_2 devices = { + {"Linksys EA3500", "linksys-audi", "mtd3", "mtd5", 32, "boot_part", 1, 2, "bootcmd", "run nandboot", "run altnandboot"}, + {"Linksys E4200v2/EA4500", "linksys-viper", "mtd3", "mtd5", 32, "boot_part", 1, 2, "bootcmd", "run nandboot", "run altnandboot"}, + {"Linksys EA8500", "ea8500", "mtd13", "mtd15", 32, "boot_part", 1, 2}, {"Linksys WRT1200AC", "armada-385-linksys-caiman", "mtd4", "mtd6", 32, "boot_part", 1, 2, "bootcmd", "run nandboot", "run altnandboot"}, {"Linksys WRT1900AC", "armada-xp-linksys-mamba", "mtd4", "mtd6", 32, "boot_part", 1, 2, "bootcmd", "run nandboot", "run altnandboot"}, {"Linksys WRT1900ACv2", "armada-385-linksys-cobra", "mtd4", "mtd6", 32, "boot_part", 1, 2, "bootcmd", "run nandboot", "run altnandboot"}, {"Linksys WRT1900ACS", "armada-385-linksys-shelby", "mtd4", "mtd6", 32, "boot_part", 1, 2, "bootcmd", "run nandboot", "run altnandboot"}, {"Linksys WRT3200ACM", "armada-385-linksys-rango", "mtd5", "mtd7", 32, "boot_part", 1, 2, "bootcmd", "run nandboot", "run altnandboot"}, - {"Linksys E4200v2/EA4500", "linksys-viper", "mtd3", "mtd5", 32, "boot_part", 1, 2, "bootcmd", "run nandboot", "run altnandboot"}, - {"Linksys EA8500", "ea8500", "mtd13", "mtd15", 32, "boot_part", 1, 2} + {"ZyXEL NBG6817","nbg6817","mmcblk0p4","mmcblk0p7",32,nil,255,1} } +errorMessage = "" board_name = luci.util.trim(luci.sys.exec("cat /tmp/sysinfo/board_name")) for i=1, #devices do if board_name and devices[i][2] == board_name then @@ -41,14 +44,29 @@ for i=1, #devices do if string.find(partition_two_label, "LEDE") then partition_two_os = "LEDE" end if string.find(partition_two_label, "OpenWrt") then partition_two_os = "OpenWrt" end if string.find(partition_two_label, "Linksys") then partition_two_os = "Linksys" end + if device_name and device_name == "ZyXEL NBG6817" then + if not partition_one_os then partition_one_os = "ZyXEL" end + if not partition_two_os then partition_two_os = "ZyXEL" end + end if not partition_one_os then partition_one_os = "Unknown" end if not partition_two_os then partition_two_os = "Unknown" end if partition_one_os and partition_one_version then partition_one_os = partition_one_os .. " (Linux " .. partition_one_version .. ")" end if partition_two_os and partition_two_version then partition_two_os = partition_two_os .. " (Linux " .. partition_two_version .. ")" end - if nixio.fs.access("/usr/sbin/fw_printenv") and nixio.fs.access("/usr/sbin/fw_setenv") then - current_partition = tonumber(luci.util.trim(luci.sys.exec("/usr/sbin/fw_printenv -n " .. boot_envvar1))) - other_partition = current_partition == boot_envvar1_partition_one and boot_envvar1_partition_two or boot_envvar1_partition_one + + if device_name and device_name == "ZyXEL NBG6817" then + if not zyxelFlagPartition then zyxelFlagPartition = luci.util.trim(luci.sys.exec("source /lib/functions.sh; find_mtd_part 0:DUAL_FLAG")) end + if not zyxelFlagPartition then + errorMessage = errorMessage .. luci.i18n.translate("Unable to find Dual Boot Flag Partition." .. " ") + luci.util.perror(luci.i18n.translate("Unable to find Dual Boot Flag Partition.")) + else + current_partition = tonumber(luci.sys.exec("dd if=" .. zyxelFlagPartition .. " bs=1 count=1 2>/dev/null | hexdump -n 1 -e '1/1 \"%d\"'")) + end + else + if nixio.fs.access("/usr/sbin/fw_printenv") and nixio.fs.access("/usr/sbin/fw_setenv") then + current_partition = tonumber(luci.util.trim(luci.sys.exec("/usr/sbin/fw_printenv -n " .. boot_envvar1))) + end end + other_partition = current_partition == boot_envvar1_partition_two and boot_envvar1_partition_one or boot_envvar1_partition_two end end @@ -70,8 +88,19 @@ function action_reboot() end function action_altreboot() + local zyxelFlagPartition, zyxelBootFlag, zyxelNewBootFlag, errorCode, curEnvSetting, newEnvSetting + errorMessage = "" + errorCode = 0 if luci.http.formvalue("cancel") then luci.http.redirect(luci.dispatcher.build_url('admin/system/advanced_reboot')) +-- luci.template.render("advanced_reboot/advanced_reboot",{ +-- device_name=device_name, +-- boot_envvar1_partition_one=boot_envvar1_partition_one, +-- partition_one_os=partition_one_os, +-- boot_envvar1_partition_two=boot_envvar1_partition_two, +-- partition_two_os=partition_two_os, +-- current_partition=current_partition, +-- errorMessage = luci.i18n.translate("Alternative reboot cancelled.")}) return end local step = tonumber(luci.http.formvalue("step") or 1) @@ -79,21 +108,72 @@ function action_altreboot() if device_name and nixio.fs.access("/usr/sbin/fw_printenv") and nixio.fs.access("/usr/sbin/fw_setenv") then luci.template.render("advanced_reboot/alternative_reboot",{}) else - luci.template.render("advanced_reboot/advanced_reboot",{}) + luci.template.render("advanced_reboot/advanced_reboot",{errorMessage = luci.i18n.translate("No access to fw_printenv or fw_printenv!")}) end elseif step == 2 then - luci.template.render("admin_system/applyreboot", { - title = luci.i18n.translate("Rebooting..."), - msg = luci.i18n.translate("The system is rebooting to an alternative partition now.<br /> DO NOT POWER OFF THE DEVICE!<br /> Wait a few minutes before you try to reconnect. It might be necessary to renew the address of your computer to reach the device again, depending on your settings."), - addr = luci.ip.new(uci.cursor():get("network", "lan", "ipaddr")) or "192.168.1.1" - }) - if boot_envvar1 then env1 = tonumber(luci.util.trim(luci.sys.exec("/usr/sbin/fw_printenv -n " .. boot_envvar1))) end - if boot_envvar2 then env2 = luci.util.trim(luci.sys.exec("/usr/sbin/fw_printenv -n " .. boot_envvar2)) end - if env1 and env1 == boot_envvar1_partition_one then luci.sys.call("/usr/sbin/fw_setenv " .. boot_envvar1 .. " " .. boot_envvar1_partition_two) end - if env1 and env1 == boot_envvar1_partition_two then luci.sys.call("/usr/sbin/fw_setenv " .. boot_envvar1 .. " " .. boot_envvar1_partition_one) end - if env2 and env2 == boot_envvar2_partition_one then luci.sys.call("/usr/sbin/fw_setenv " .. boot_envvar2 .. " '" .. boot_envvar2_partition_two .. "'") end - if env2 and env2 == boot_envvar2_partition_two then luci.sys.call("/usr/sbin/fw_setenv " .. boot_envvar2 .. " '" .. boot_envvar2_partition_one .. "'") end - luci.sys.reboot() + if boot_envvar1 or boot_envvar2 then -- Linksys devices + if boot_envvar1 then + curEnvSetting = tonumber(luci.util.trim(luci.sys.exec("/usr/sbin/fw_printenv -n " .. boot_envvar1))) + if not curEnvSetting then + errorMessage = errorMessage .. luci.i18n.translate("Unable to obtain firmware environment variable") .. ": " .. boot_envvar1 .. ". " + luci.util.perror(luci.i18n.translate("Unable to obtain firmware environment variable") .. ": " .. boot_envvar1 .. ".") + else + newEnvSetting = curEnvSetting == boot_envvar1_partition_one and boot_envvar1_partition_two or boot_envvar1_partition_one + errorCode = luci.sys.call("/usr/sbin/fw_setenv " .. boot_envvar1 .. " " .. newEnvSetting) + if errorCode ~= 0 then + errorMessage = errorMessage .. luci.i18n.translate("Unable to set firmware environment variable") .. ": " .. boot_envvar1 .. " " .. luci.i18n.translate("to") .. " " .. newEnvSetting .. ". " + luci.util.perror(luci.i18n.translate("Unable to set firmware environment variable") .. ": " .. boot_envvar1 .. " " .. luci.i18n.translate("to") .. " " .. newEnvSetting .. ".") + end + end + end + if boot_envvar2 then + curEnvSetting = luci.util.trim(luci.sys.exec("/usr/sbin/fw_printenv -n " .. boot_envvar2)) + if not curEnvSetting then + errorMessage = errorMessage .. luci.i18n.translate("Unable to obtain firmware environment variable") .. ": " .. boot_envvar2 .. ". " + luci.util.perror(luci.i18n.translate("Unable to obtain firmware environment variable") .. ": " .. boot_envvar2 .. ".") + else + newEnvSetting = curEnvSetting == boot_envvar2_partition_one and boot_envvar2_partition_two or boot_envvar2_partition_one + errorCode = luci.sys.call("/usr/sbin/fw_setenv " .. boot_envvar2 .. " '" .. newEnvSetting .. "'") + if errorCode ~= 0 then + errorMessage = errorMessage .. luci.i18n.translate("Unable to set firmware environment variable") .. ": " .. boot_envvar2 .. " " .. luci.i18n.translate("to") .. " " .. newEnvSetting .. ". " + luci.util.perror(luci.i18n.translate("Unable to set firmware environment variable") .. ": " .. boot_envvar2 .. " " .. luci.i18n.translate("to") .. " " .. newEnvSetting .. ".") + end + end + end + else -- NetGear device + if not zyxelFlagPartition then zyxelFlagPartition = luci.util.trim(luci.sys.exec("source /lib/functions.sh; find_mtd_part 0:DUAL_FLAG")) end + if not zyxelFlagPartition then + errorMessage = errorMessage .. luci.i18n.translate("Unable to find Dual Boot Flag Partition." .. " ") + luci.util.perror(luci.i18n.translate("Unable to find Dual Boot Flag Partition.")) + else + zyxelBootFlag = tonumber(luci.sys.exec("dd if=" .. zyxelFlagPartition .. " bs=1 count=1 2>/dev/null | hexdump -n 1 -e '1/1 \"%d\"'")) + zyxelNewBootFlag = zyxelBootFlag and zyxelBootFlag == 1 and "\\xff" or "\\x01" + if zyxelNewBootFlag then + errorCode = luci.sys.call("printf \"" .. zyxelNewBootFlag .. "\" >" .. zyxelFlagPartition ) + if errorCode ~= 0 then + errorMessage = errorMessage .. luci.i18n.translate("Unable to set Dual Boot Flag Partition entry for partition") .. ": " .. zyxelFlagPartition .. ". " + luci.util.perror(luci.i18n.translate("Unable to set Dual Boot Flag Partition entry for partition") .. ": " .. zyxelFlagPartition .. ".") + end + end + end + end + if errorMessage == "" then + luci.template.render("admin_system/applyreboot", { + title = luci.i18n.translate("Rebooting..."), + msg = luci.i18n.translate("The system is rebooting to an alternative partition now.<br /> DO NOT POWER OFF THE DEVICE!<br /> Wait a few minutes before you try to reconnect. It might be necessary to renew the address of your computer to reach the device again, depending on your settings."), + addr = luci.ip.new(uci.cursor():get("network", "lan", "ipaddr")) or "192.168.1.1" + }) + luci.sys.reboot() + else + luci.template.render("advanced_reboot/advanced_reboot",{ + device_name=device_name, + boot_envvar1_partition_one=boot_envvar1_partition_one, + partition_one_os=partition_one_os, + boot_envvar1_partition_two=boot_envvar1_partition_two, + partition_two_os=partition_two_os, + current_partition=current_partition, + errorMessage = errorMessage}) + end end end diff --git a/applications/luci-app-advanced-reboot/luasrc/view/advanced_reboot/advanced_reboot.htm b/applications/luci-app-advanced-reboot/luasrc/view/advanced_reboot/advanced_reboot.htm index 206d25054..0629c84b3 100644 --- a/applications/luci-app-advanced-reboot/luasrc/view/advanced_reboot/advanced_reboot.htm +++ b/applications/luci-app-advanced-reboot/luasrc/view/advanced_reboot/advanced_reboot.htm @@ -14,6 +14,10 @@ <p class="alert-message warning"><%:Warning: There are unsaved changes that will get lost on reboot!%></p> <%- end -%> +<%- if errorMessage and errorMessage ~= "" then -%> + <p class="alert-message warning"><%:ERROR: %><%=errorMessage%></p> +<%- end -%> + <%- if device_name then -%> <fieldset class="cbi-section"> <legend><%=device_name%><%: Partitions%></legend> @@ -26,7 +30,7 @@ </tr> <tr class="cbi-section-table-row"> <td> - <%=boot_envvar1_partition_one%> + <%=string.format("%X", boot_envvar1_partition_one)%> </td> <td> <%- if boot_envvar1_partition_one == current_partition then -%><%:Current%><%- else -%><%:Alternative%><%- end -%> @@ -50,7 +54,7 @@ </tr> <tr class="cbi-section-table-row"> <td> - <%=boot_envvar1_partition_two%> + <%=string.format("%X", boot_envvar1_partition_two)%> </td> <td> <%- if boot_envvar1_partition_two == current_partition then -%><%:Current%><%- else -%><%:Alternative%><%- end -%> |