From 54e989ec3a2d9c6928047ea09a3d6053cbf2441f Mon Sep 17 00:00:00 2001 From: Adin Scannell Date: Mon, 19 Oct 2020 16:26:42 -0700 Subject: Remove legacy bazel configurations. Using the newer bazel rules necessitates a transition from proto1 to proto2. In order to resolve the incompatibility between proto2 and gogoproto, the cri runtimeoptions proto must be vendored. Further, some of the semantics of bazel caching changed during the transition. It is now necessary to: - Ensure that :gopath depends only on pure library targets, as the propagation of go_binary build attributes (pure, static) will affected the generated files (though content remains the same, there are conflicts with respect to the gopath). - Update bazel.mk to include the possibility of binaries in the bazel-out directory, as it will now put runsc and others there. This required some refinements to the mechanism of extracting paths, since some the existing regex resulted in false positives. - Change nogo rules to prevent escape generation on binary targets. For some reason, the newer version of bazel attempted to run the nogo analysis on the binary targets, which fails due to the fact that objdump does not work on the final binary. This must be due to a change in the semantics of aspects in bazel3. PiperOrigin-RevId: 337958324 --- runsc/cli/BUILD | 22 +++++ runsc/cli/main.go | 256 ++++++++++++++++++++++++++++++++++++++++++++++++++++++ 2 files changed, 278 insertions(+) create mode 100644 runsc/cli/BUILD create mode 100644 runsc/cli/main.go (limited to 'runsc/cli') diff --git a/runsc/cli/BUILD b/runsc/cli/BUILD new file mode 100644 index 000000000..32cce2a18 --- /dev/null +++ b/runsc/cli/BUILD @@ -0,0 +1,22 @@ +load("//tools:defs.bzl", "go_library") + +package(licenses = ["notice"]) + +go_library( + name = "cli", + srcs = ["main.go"], + visibility = [ + "//:__pkg__", + "//runsc:__pkg__", + ], + deps = [ + "//pkg/log", + "//pkg/refs", + "//pkg/sentry/platform", + "//runsc/cmd", + "//runsc/config", + "//runsc/flag", + "//runsc/specutils", + "@com_github_google_subcommands//:go_default_library", + ], +) diff --git a/runsc/cli/main.go b/runsc/cli/main.go new file mode 100644 index 000000000..bca015db5 --- /dev/null +++ b/runsc/cli/main.go @@ -0,0 +1,256 @@ +// Copyright 2018 The gVisor Authors. +// +// Licensed under the Apache License, Version 2.0 (the "License"); +// you may not use this file except in compliance with the License. +// You may obtain a copy of the License at +// +// http://www.apache.org/licenses/LICENSE-2.0 +// +// Unless required by applicable law or agreed to in writing, software +// distributed under the License is distributed on an "AS IS" BASIS, +// WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. +// See the License for the specific language governing permissions and +// limitations under the License. + +// Package cli is the main entrypoint for runsc. +package cli + +import ( + "context" + "fmt" + "io" + "io/ioutil" + "os" + "os/signal" + "syscall" + "time" + + "github.com/google/subcommands" + "gvisor.dev/gvisor/pkg/log" + "gvisor.dev/gvisor/pkg/refs" + "gvisor.dev/gvisor/pkg/sentry/platform" + "gvisor.dev/gvisor/runsc/cmd" + "gvisor.dev/gvisor/runsc/config" + "gvisor.dev/gvisor/runsc/flag" + "gvisor.dev/gvisor/runsc/specutils" +) + +var ( + // Although these flags are not part of the OCI spec, they are used by + // Docker, and thus should not be changed. + // TODO(gvisor.dev/issue/193): support systemd cgroups + systemdCgroup = flag.Bool("systemd-cgroup", false, "Use systemd for cgroups. NOT SUPPORTED.") + showVersion = flag.Bool("version", false, "show version and exit.") + + // These flags are unique to runsc, and are used to configure parts of the + // system that are not covered by the runtime spec. + + // Debugging flags. + logFD = flag.Int("log-fd", -1, "file descriptor to log to. If set, the 'log' flag is ignored.") + debugLogFD = flag.Int("debug-log-fd", -1, "file descriptor to write debug logs to. If set, the 'debug-log-dir' flag is ignored.") + panicLogFD = flag.Int("panic-log-fd", -1, "file descriptor to write Go's runtime messages.") +) + +// Main is the main entrypoint. +func Main(version string) { + // Help and flags commands are generated automatically. + help := cmd.NewHelp(subcommands.DefaultCommander) + help.Register(new(cmd.Syscalls)) + subcommands.Register(help, "") + subcommands.Register(subcommands.FlagsCommand(), "") + + // Installation helpers. + const helperGroup = "helpers" + subcommands.Register(new(cmd.Install), helperGroup) + subcommands.Register(new(cmd.Uninstall), helperGroup) + + // Register user-facing runsc commands. + subcommands.Register(new(cmd.Checkpoint), "") + subcommands.Register(new(cmd.Create), "") + subcommands.Register(new(cmd.Delete), "") + subcommands.Register(new(cmd.Do), "") + subcommands.Register(new(cmd.Events), "") + subcommands.Register(new(cmd.Exec), "") + subcommands.Register(new(cmd.Gofer), "") + subcommands.Register(new(cmd.Kill), "") + subcommands.Register(new(cmd.List), "") + subcommands.Register(new(cmd.Pause), "") + subcommands.Register(new(cmd.PS), "") + subcommands.Register(new(cmd.Restore), "") + subcommands.Register(new(cmd.Resume), "") + subcommands.Register(new(cmd.Run), "") + subcommands.Register(new(cmd.Spec), "") + subcommands.Register(new(cmd.State), "") + subcommands.Register(new(cmd.Start), "") + subcommands.Register(new(cmd.Wait), "") + + // Register internal commands with the internal group name. This causes + // them to be sorted below the user-facing commands with empty group. + // The string below will be printed above the commands. + const internalGroup = "internal use only" + subcommands.Register(new(cmd.Boot), internalGroup) + subcommands.Register(new(cmd.Debug), internalGroup) + subcommands.Register(new(cmd.Gofer), internalGroup) + subcommands.Register(new(cmd.Statefile), internalGroup) + + config.RegisterFlags() + + // All subcommands must be registered before flag parsing. + flag.Parse() + + // Are we showing the version? + if *showVersion { + // The format here is the same as runc. + fmt.Fprintf(os.Stdout, "runsc version %s\n", version) + fmt.Fprintf(os.Stdout, "spec: %s\n", specutils.Version) + os.Exit(0) + } + + // Create a new Config from the flags. + conf, err := config.NewFromFlags() + if err != nil { + cmd.Fatalf(err.Error()) + } + + // TODO(gvisor.dev/issue/193): support systemd cgroups + if *systemdCgroup { + fmt.Fprintln(os.Stderr, "systemd cgroup flag passed, but systemd cgroups not supported. See gvisor.dev/issue/193") + os.Exit(1) + } + + var errorLogger io.Writer + if *logFD > -1 { + errorLogger = os.NewFile(uintptr(*logFD), "error log file") + + } else if conf.LogFilename != "" { + // We must set O_APPEND and not O_TRUNC because Docker passes + // the same log file for all commands (and also parses these + // log files), so we can't destroy them on each command. + var err error + errorLogger, err = os.OpenFile(conf.LogFilename, os.O_WRONLY|os.O_CREATE|os.O_APPEND, 0644) + if err != nil { + cmd.Fatalf("error opening log file %q: %v", conf.LogFilename, err) + } + } + cmd.ErrorLogger = errorLogger + + if _, err := platform.Lookup(conf.Platform); err != nil { + cmd.Fatalf("%v", err) + } + + // Sets the reference leak check mode. Also set it in config below to + // propagate it to child processes. + refs.SetLeakMode(conf.ReferenceLeak) + + // Set up logging. + if conf.Debug { + log.SetLevel(log.Debug) + } + + // Logging will include the local date and time via the time package. + // + // On first use, time.Local initializes the local time zone, which + // involves opening tzdata files on the host. Since this requires + // opening host files, it must be done before syscall filter + // installation. + // + // Generally there will be a log message before filter installation + // that will force initialization, but force initialization here in + // case that does not occur. + _ = time.Local.String() + + subcommand := flag.CommandLine.Arg(0) + + var e log.Emitter + if *debugLogFD > -1 { + f := os.NewFile(uintptr(*debugLogFD), "debug log file") + + e = newEmitter(conf.DebugLogFormat, f) + + } else if conf.DebugLog != "" { + f, err := specutils.DebugLogFile(conf.DebugLog, subcommand, "" /* name */) + if err != nil { + cmd.Fatalf("error opening debug log file in %q: %v", conf.DebugLog, err) + } + e = newEmitter(conf.DebugLogFormat, f) + + } else { + // Stderr is reserved for the application, just discard the logs if no debug + // log is specified. + e = newEmitter("text", ioutil.Discard) + } + + if *panicLogFD > -1 || *debugLogFD > -1 { + fd := *panicLogFD + if fd < 0 { + fd = *debugLogFD + } + // Quick sanity check to make sure no other commands get passed + // a log fd (they should use log dir instead). + if subcommand != "boot" && subcommand != "gofer" { + cmd.Fatalf("flags --debug-log-fd and --panic-log-fd should only be passed to 'boot' and 'gofer' command, but was passed to %q", subcommand) + } + + // If we are the boot process, then we own our stdio FDs and can do what we + // want with them. Since Docker and Containerd both eat boot's stderr, we + // dup our stderr to the provided log FD so that panics will appear in the + // logs, rather than just disappear. + if err := syscall.Dup3(fd, int(os.Stderr.Fd()), 0); err != nil { + cmd.Fatalf("error dup'ing fd %d to stderr: %v", fd, err) + } + } else if conf.AlsoLogToStderr { + e = &log.MultiEmitter{e, newEmitter(conf.DebugLogFormat, os.Stderr)} + } + + log.SetTarget(e) + + log.Infof("***************************") + log.Infof("Args: %s", os.Args) + log.Infof("Version %s", version) + log.Infof("PID: %d", os.Getpid()) + log.Infof("UID: %d, GID: %d", os.Getuid(), os.Getgid()) + log.Infof("Configuration:") + log.Infof("\t\tRootDir: %s", conf.RootDir) + log.Infof("\t\tPlatform: %v", conf.Platform) + log.Infof("\t\tFileAccess: %v, overlay: %t", conf.FileAccess, conf.Overlay) + log.Infof("\t\tNetwork: %v, logging: %t", conf.Network, conf.LogPackets) + log.Infof("\t\tStrace: %t, max size: %d, syscalls: %s", conf.Strace, conf.StraceLogSize, conf.StraceSyscalls) + log.Infof("\t\tVFS2 enabled: %v", conf.VFS2) + log.Infof("***************************") + + if conf.TestOnlyAllowRunAsCurrentUserWithoutChroot { + // SIGTERM is sent to all processes if a test exceeds its + // timeout and this case is handled by syscall_test_runner. + log.Warningf("Block the TERM signal. This is only safe in tests!") + signal.Ignore(syscall.SIGTERM) + } + + // Call the subcommand and pass in the configuration. + var ws syscall.WaitStatus + subcmdCode := subcommands.Execute(context.Background(), conf, &ws) + if subcmdCode == subcommands.ExitSuccess { + log.Infof("Exiting with status: %v", ws) + if ws.Signaled() { + // No good way to return it, emulate what the shell does. Maybe raise + // signal to self? + os.Exit(128 + int(ws.Signal())) + } + os.Exit(ws.ExitStatus()) + } + // Return an error that is unlikely to be used by the application. + log.Warningf("Failure to execute command, err: %v", subcmdCode) + os.Exit(128) +} + +func newEmitter(format string, logFile io.Writer) log.Emitter { + switch format { + case "text": + return log.GoogleEmitter{&log.Writer{Next: logFile}} + case "json": + return log.JSONEmitter{&log.Writer{Next: logFile}} + case "json-k8s": + return log.K8sJSONEmitter{&log.Writer{Next: logFile}} + } + cmd.Fatalf("invalid log format %q, must be 'text', 'json', or 'json-k8s'", format) + panic("unreachable") +} -- cgit v1.2.3