diff options
author | gVisor bot <gvisor-bot@google.com> | 2019-10-24 23:55:44 +0000 |
---|---|---|
committer | gVisor bot <gvisor-bot@google.com> | 2019-10-24 23:55:44 +0000 |
commit | d77656f68442d63fdac6705787b5539df8de6cc3 (patch) | |
tree | 6e18d4f7c116bd908182b83be90a31f74166f64a /pkg | |
parent | f28ef1dc3e099688325c92248832ae1947560f0a (diff) | |
parent | 27e896f2905eea612855b1c92d9b43ebaa09cbf3 (diff) |
Merge release-20190806.1-322-g27e896f (automated)
Diffstat (limited to 'pkg')
-rwxr-xr-x | pkg/tcpip/header/ndp_options.go | 164 |
1 files changed, 164 insertions, 0 deletions
diff --git a/pkg/tcpip/header/ndp_options.go b/pkg/tcpip/header/ndp_options.go index b28bde15b..98310ea23 100755 --- a/pkg/tcpip/header/ndp_options.go +++ b/pkg/tcpip/header/ndp_options.go @@ -15,6 +15,9 @@ package header import ( + "encoding/binary" + "time" + "gvisor.dev/gvisor/pkg/tcpip" ) @@ -27,6 +30,65 @@ const ( // Link Layer Option for an Ethernet address. ndpTargetEthernetLinkLayerAddressSize = 8 + // ndpPrefixInformationType is the type of the Prefix Information + // option, as per RFC 4861 section 4.6.2. + ndpPrefixInformationType = 3 + + // ndpPrefixInformationLength is the expected length, in bytes, of the + // body of an NDP Prefix Information option, as per RFC 4861 section + // 4.6.2 which specifies that the Length field is 4. Given this, the + // expected length, in bytes, is 30 becuase 4 * lengthByteUnits (8) - 2 + // (Type & Length) = 30. + ndpPrefixInformationLength = 30 + + // ndpPrefixInformationPrefixLengthOffset is the offset of the Prefix + // Length field within an NDPPrefixInformation. + ndpPrefixInformationPrefixLengthOffset = 0 + + // ndpPrefixInformationFlagsOffset is the offset of the flags byte + // within an NDPPrefixInformation. + ndpPrefixInformationFlagsOffset = 1 + + // ndpPrefixInformationOnLinkFlagMask is the mask of the On-Link Flag + // field in the flags byte within an NDPPrefixInformation. + ndpPrefixInformationOnLinkFlagMask = (1 << 7) + + // ndpPrefixInformationAutoAddrConfFlagMask is the mask of the + // Autonomous Address-Configuration flag field in the flags byte within + // an NDPPrefixInformation. + ndpPrefixInformationAutoAddrConfFlagMask = (1 << 6) + + // ndpPrefixInformationReserved1FlagsMask is the mask of the Reserved1 + // field in the flags byte within an NDPPrefixInformation. + ndpPrefixInformationReserved1FlagsMask = 63 + + // ndpPrefixInformationValidLifetimeOffset is the start of the 4-byte + // Valid Lifetime field within an NDPPrefixInformation. + ndpPrefixInformationValidLifetimeOffset = 2 + + // ndpPrefixInformationPreferredLifetimeOffset is the start of the + // 4-byte Preferred Lifetime field within an NDPPrefixInformation. + ndpPrefixInformationPreferredLifetimeOffset = 6 + + // ndpPrefixInformationReserved2Offset is the start of the 4-byte + // Reserved2 field within an NDPPrefixInformation. + ndpPrefixInformationReserved2Offset = 10 + + // ndpPrefixInformationReserved2Length is the length of the Reserved2 + // field. + // + // It is 4 bytes. + ndpPrefixInformationReserved2Length = 4 + + // ndpPrefixInformationPrefixOffset is the start of the Prefix field + // within an NDPPrefixInformation. + ndpPrefixInformationPrefixOffset = 14 + + // NDPPrefixInformationInfiniteLifetime is a value that represents + // infinity for the Valid and Preferred Lifetime fields in a NDP Prefix + // Information option. Its value is (2^32 - 1)s = 4294967295s + NDPPrefixInformationInfiniteLifetime = time.Second * 4294967295 + // lengthByteUnits is the multiplier factor for the Length field of an // NDP option. That is, the length field for NDP options is in units of // 8 octets, as per RFC 4861 section 4.6. @@ -154,6 +216,9 @@ func (b NDPOptionsSerializer) Length() int { // NDPTargetLinkLayerAddressOption is the NDP Target Link Layer Option // as defined by RFC 4861 section 4.6.1. +// +// It is the first X bytes following the NDP option's Type and Length field +// where X is the value in Length multiplied by lengthByteUnits - 2 bytes. type NDPTargetLinkLayerAddressOption tcpip.LinkAddress // Type implements ndpOption.Type. @@ -170,3 +235,102 @@ func (o NDPTargetLinkLayerAddressOption) Length() int { func (o NDPTargetLinkLayerAddressOption) serializeInto(b []byte) int { return copy(b, o) } + +// NDPPrefixInformation is the NDP Prefix Information option as defined by +// RFC 4861 section 4.6.2. +// +// The length, in bytes, of a valid NDP Prefix Information option body MUST be +// ndpPrefixInformationLength bytes. +type NDPPrefixInformation []byte + +// Type implements ndpOption.Type. +func (o NDPPrefixInformation) Type() uint8 { + return ndpPrefixInformationType +} + +// Length implements ndpOption.Length. +func (o NDPPrefixInformation) Length() int { + return ndpPrefixInformationLength +} + +// serializeInto implements ndpOption.serializeInto. +func (o NDPPrefixInformation) serializeInto(b []byte) int { + used := copy(b, o) + + // Zero out the Reserved1 field. + b[ndpPrefixInformationFlagsOffset] &^= ndpPrefixInformationReserved1FlagsMask + + // Zero out the Reserved2 field. + reserved2 := b[ndpPrefixInformationReserved2Offset:][:ndpPrefixInformationReserved2Length] + for i := range reserved2 { + reserved2[i] = 0 + } + + return used +} + +// PrefixLength returns the value in the number of leading bits in the Prefix +// that are valid. +// +// Valid values are in the range [0, 128], but o may not always contain valid +// values. It is up to the caller to valdiate the Prefix Information option. +func (o NDPPrefixInformation) PrefixLength() uint8 { + return o[ndpPrefixInformationPrefixLengthOffset] +} + +// OnLinkFlag returns true of the prefix is considered on-link. On-link means +// that a forwarding node is not needed to send packets to other nodes on the +// same prefix. +// +// Note, when this function returns false, no statement is made about the +// on-link property of a prefix. That is, if OnLinkFlag returns false, the +// caller MUST NOT conclude that the prefix is off-link and MUST NOT update any +// previously stored state for this prefix about its on-link status. +func (o NDPPrefixInformation) OnLinkFlag() bool { + return o[ndpPrefixInformationFlagsOffset]&ndpPrefixInformationOnLinkFlagMask != 0 +} + +// AutonomousAddressConfigurationFlag returns true if the prefix can be used for +// Stateless Address Auto-Configuration (as specified in RFC 4862). +func (o NDPPrefixInformation) AutonomousAddressConfigurationFlag() bool { + return o[ndpPrefixInformationFlagsOffset]&ndpPrefixInformationAutoAddrConfFlagMask != 0 +} + +// ValidLifetime returns the length of time that the prefix is valid for the +// purpose of on-link determination. This value is relative to the send time of +// the packet that the Prefix Information option was present in. +// +// Note, a value of 0 implies the prefix should not be considered as on-link, +// and a value of infinity/forever is represented by +// NDPPrefixInformationInfiniteLifetime. +func (o NDPPrefixInformation) ValidLifetime() time.Duration { + // The field is the time in seconds, as per RFC 4861 section 4.6.2. + return time.Second * time.Duration(binary.BigEndian.Uint32(o[ndpPrefixInformationValidLifetimeOffset:])) +} + +// PreferredLifetime returns the length of time that an address generated from +// the prefix via Stateless Address Auto-Configuration remains preferred. This +// value is relative to the send time of the packet that the Prefix Information +// option was present in. +// +// Note, a value of 0 implies that addresses generated from the prefix should +// no longer remain preferred, and a value of infinity is represented by +// NDPPrefixInformationInfiniteLifetime. +// +// Also note that the value of this field MUST NOT exceed the Valid Lifetime +// field to avoid preferring addresses that are no longer valid, for the +// purpose of Stateless Address Auto-Configuration. +func (o NDPPrefixInformation) PreferredLifetime() time.Duration { + // The field is the time in seconds, as per RFC 4861 section 4.6.2. + return time.Second * time.Duration(binary.BigEndian.Uint32(o[ndpPrefixInformationPreferredLifetimeOffset:])) +} + +// Prefix returns an IPv6 address or a prefix of an IPv6 address. The Prefix +// Length field (see NDPPrefixInformation.PrefixLength) contains the number +// of valid leading bits in the prefix. +// +// Hosts SHOULD ignore an NDP Prefix Information option where the Prefix field +// holds the link-local prefix (fe80::). +func (o NDPPrefixInformation) Prefix() tcpip.Address { + return tcpip.Address(o[ndpPrefixInformationPrefixOffset:][:IPv6AddressSize]) +} |