diff options
author | newmanwang <wcs1011@gmail.com> | 2018-09-14 17:38:16 -0700 |
---|---|---|
committer | Shentubot <shentubot@google.com> | 2018-09-14 17:39:25 -0700 |
commit | de5a590ee203b4ee217da68dbec8e58a7753e520 (patch) | |
tree | 528840952692a76a9559806086f69bdb6da94ea8 /pkg/sentry/platform/ptrace | |
parent | 75c66f871b56a8f4e83dc9ccec29cf3d2c38fea4 (diff) |
Avoid reuse of pending SignalInfo objects
runApp.execute -> Task.SendSignal -> sendSignalLocked -> sendSignalTimerLocked
-> pendingSignals.enqueue assumes that it owns the arch.SignalInfo returned
from platform.Context.Switch.
On the other hand, ptrace.context.Switch assumes that it owns the returned
SignalInfo and can safely reuse it on the next call to Switch. The KVM platform
always returns a unique SignalInfo.
This becomes a problem when the returned signal is not immediately delivered,
allowing a future signal in Switch to change the previous pending SignalInfo.
This is noticeable in #38 when external SIGINTs are delivered from the PTY
slave FD. Note that the ptrace stubs are in the same process group as the
sentry, so they are eligible to receive the PTY signals. This should probably
change, but is not the only possible cause of this bug.
Updates #38
Original change by newmanwang <wcs1011@gmail.com>, updated by Michael Pratt
<mpratt@google.com>.
Change-Id: I5383840272309df70a29f67b25e8221f933622cd
PiperOrigin-RevId: 213071072
Diffstat (limited to 'pkg/sentry/platform/ptrace')
-rw-r--r-- | pkg/sentry/platform/ptrace/ptrace.go | 7 |
1 files changed, 5 insertions, 2 deletions
diff --git a/pkg/sentry/platform/ptrace/ptrace.go b/pkg/sentry/platform/ptrace/ptrace.go index a44f549a2..4f20716f7 100644 --- a/pkg/sentry/platform/ptrace/ptrace.go +++ b/pkg/sentry/platform/ptrace/ptrace.go @@ -142,9 +142,12 @@ func (c *context) Switch(as platform.AddressSpace, ac arch.Context, cpu int32) ( if isSyscall { return nil, usermem.NoAccess, nil } + + si := c.signalInfo + if faultSP == nil { // Non-fault signal. - return &c.signalInfo, usermem.NoAccess, platform.ErrContextSignal + return &si, usermem.NoAccess, platform.ErrContextSignal } // Got a page fault. Ideally, we'd get real fault type here, but ptrace @@ -168,7 +171,7 @@ func (c *context) Switch(as platform.AddressSpace, ac arch.Context, cpu int32) ( // here, in case this fault was generated by a CPUID exception. There // is no way to distinguish between CPUID-generated faults and regular // page faults. - return &c.signalInfo, at, platform.ErrContextSignalCPUID + return &si, at, platform.ErrContextSignalCPUID } // Interrupt interrupts the running guest application associated with this context. |